6TADLP728-1E
TOTAL ACCESS 3000/3010
DLP-728
Page 2 of 4
Perform Steps Below in the Order Listed
1.1.3 Prerequisite Procedures (Y-modem)
The following procedures must be completed prior to attempting a software upgrade
on the SCU using Y-modem. The Y-modem protocol may be used over a variety of
transmission mediums. The prerequisites listed below have qualifying statements. If
the particular transmission medium is not going to be used, skip the corresponding
prerequisite procedure. If necessary, refer to the appropriate documentation before
proceeding. The prerequisite procedures include:
Installation and wiring of a Total Access 3000/3010 shelf and SCU – NTP-501
Making RS-485 Bus Connections Between Shelves – DLP-712 (This prerequisite
need only be completed if communicating with client shelves using the RS-485
Bus)
Connecting the Shelf to an External Modem – DLP-713 (This prerequisite need
only be completed if communicating with the shelf using an external modem)
Setting IP Parameters for an SCU – DLP-718 (IP Parameters are only considered a
prerequisite if using IP over Ethernet or the inband management channel)
1.1.4
Materials Required
Total Access 3000/3010 System Controller Unit
Management connection to the Total Access 3000/3010
1.2
Upgrading the SCU using TFTP
1. Save the new firmware file onto a TFTP server reachable by the Total Access
3000/3010 SCU that is to be upgraded.
2. Logon to the SCU.
© 2003, ADTRAN, Inc.
For details, go to: DLP-716.
Total Access 3000/3010 System Manual