After unpacking the unit, inspect it for damage. If the equipment has been damaged,
file a claim with the carrier and then contact ADTRAN Customer Service.
1.3.2
Install the Working DS3 MUX
1.
Gently but firmly push the DS3 MUX into the second slot, slot A, at the left
end of the shelf. Simultaneous thumb pressure at the top (above the POWER
LED) and bottom (below the Test/Enable button) of the unit will ensure a good
seat of the DS3 pins into the backplane connector. Push the ejector tab up and
closed against the DS3 faceplate.
2.
Allow the self-test LED sequence to complete. The self-test should take about
10-15 seconds. Upon completion, the POWER LED will be yellow, indicating
the unit is Out-of-Service and the STATUS LED will be off, indicating the unit
is in the Unassigned (OOS-UA) state. The ONLINE LED will also be off. The
ONLINE LED will remain off until the unit is placed in the Out-of-Service,
Maintenance, or In-Service state. No alarms will be passed on to the network
until the unit is placed in the In-Service state.
3.
If a single mux configuration is being employed, proceed to DLP-740 for the
procedure to provision the DS3 MUX Module. If a protection configuration is
being employed, proceed to DLP-740 after the Protect MUX module has been
installed.
1.4
Protect MUX (slot B) Installation Procedure
1.4.1
Unpack and Inspect the Protect DS3 MUX Module
Each DS3 MUX Module is shipped in its own cardboard shipping carton. Open the
carton carefully and avoid deep penetration into the carton with sharp objects. After
removing the unit from the carton, unwrap the bubble-wrap and pull the unit from the
antistatic plastic bag.
After unpacking the unit, inspect it for damage. If the equipment has been damaged,
file a claim with the carrier and then contact ADTRAN Customer Service.
1.4.2
Install the Protect DS3 MUX
1.
Gently but firmly push the DS3 MUX into the third slot, slot B, at the left end of
the shelf. Simultaneous thumb pressure at the top (above the POWER LED) and
bottom (below the Test/Enable button) of the unit will ensure a good seat of the
DS3 pins into the backplane connector. Push the ejector tab up and closed
against the DS3 faceplate.
2.
Allow the self-test LED sequence to complete. The self-test should take about
10-15 seconds. Upon completion, the POWER LED will be yellow, indicating
the unit is Out-of-Service and the STATUS LED will be off indicating the unit is
in the Unassigned (OOS-UA) state. The ONLINE LED will also be off.