Operation guide | iSave 40
58
5.
To disconnect the bell housing, unscrew
the 4 bolts on the electric motor.
7.
Disassemble the bell housing from the
booster pump by unscrewing the 4
bolts in the bell housing.
9.
After the pressure exchanger is released
from the booster pump, remove the two
guide pins and the O - rings.
180R9239 | AQ299555093252en-001601 | iSave 40 | 09.2022
6.
Carefully pull and lift the booster pump
from the electric motor.
8.
It is also possible to disconnect the
complete unit from the motor first.
In this case, please follow step 1, 5, 6
and 7 afterwards. Assembly of the
unit in reverse order.