20

6.3 Orientation

The iSave 40 can be mounted horizontally and
vertically.
When mounted vertically, the electric motor
must be placed above the iSave.

6.4 Piping and joints

Piping material and schedule is of high impor-
tance. The strength of the Victaulic® connections
is influenced by the material used for both the
Victaulic® clamps and the hard piping.
The hard piping and connections used must be
of proper design and must be installed in
Correct piping alignment
The hard piping and connections used
must be of proper design and must be
installed in accordance with the manufac-
turer's recommendations.
A failure to comply with this will or may
result in personal injury and/or damage
to the iSave.
Misalignment of the hard pipes may place
stress on the iSave port connection and
may damage the iSave.

6.5 Flexible couplings and flexible hoses.

The strength of the Victaulic® connections is
influenced by the material used for both the
Victaulic® clamps and hose couplings.
See also "Hose assembly and installation" in
appendix 10.7.
The flexible hose and connections used
must be of proper design and must be
installed in accordance with the manu-
facturer's recommendations.
A failure to comply with this will or may
result in personal injury and/or damage
to the iSave.
180R9239 | AQ299555093252en-001601 | iSave 40 | 09.2022
accordance with the manufacturer's recommen-
dations.
Hard piping to the iSave must be properly
aligned to avoid stress on the iSave port
connections. Pipe connections must be aligned
as shown in the figures below.
Danfoss recommends installing hose whip
restraints whenever your pressurized hose
assemblies are in proximity to personnel or
crucial equipment.
Don't use the iSave as a strain for hard piping.
Incorrect piping alignment

6.6 Mounting of coupling

The figure below illustrates how to mount the
flexible coupling between the iSave and to
connect it to the electric motor.
A:
Flexible coupling
B:
Bell housing
C:
Motor shaft
Any axial and radial load on the shaft
must be avoided.
!
Incorrect piping alignment