Operation guide | iSave 40
Media filter
PI
1
Fresh water
permeate flush
*
second stage filter,
see box below
18
5.16 Preferred system design and P&ID
Filter
Filter
PI
Filter
3
5 micron
3 micron
10 micron
nominel
2
PS
PI
nominel
absolut
12
LP in
HP out
*
11
iSave
HP in
VFD
19
*
Second stage filter: If recommended housing design and cartridges are not used, a second stage filter is required
5.17 Explanation of P&ID setup
• The pressure switch (3) must stop the
iSave (11) and the high-pressure pump
(4) at pressures lower than the minimum
inlet pressure or higher than the
allowable maximum pressure.
• The non-return valve (18) prevents the
high-pressure flow from the membrane
to flow back through the HP pump and
into the low pressure piping. This may
occur when the high-pressure pump
stops.
• The pressure relief valve (6) protects the
entire system against pressure overload
and relieves the water if the pressure
exceeds the maximum set pressure.
If the high pressure pump is a positive
displacement pump, the pump can build
up a very high pressure that will exceed
the mechanical strength of the mem-
brane housing, pipes and other
accessories.
• The valve (8) bleeds the air out of the
system. The valve must be placed at the
highest point in the system.
• The pressure relief valve (19) protects
the low pressure pipes against pressure
overload and relieves the water if the
pressure exceeds the maximum
allowable pressure.
180R9239 | AQ299555093252en-001601 | iSave 40 | 09.2022
VFD
4
PI
6
5
PS
18
Full flow
cleaning
7
10
PI
13
14
15
PS
20
PI
See "Start and stop" procedure, "Membrane
cleaning" procedure and "iSave overload
protection" instructions in appendices 10.2, 10.3.
and 10.6.
17
Permeate
Flowmeter
8
9
16
28
CIP
27
Drain
• Inlet filters assure proper water quality.
High quality water extends the service
life of the whole system.
• It is important with selection of a
proper filter housing to ensure good
cartridge end sealing. If there is a high
risk of water by-pass it is recommended
to use a second stage filter solution.
• The pressure switch (13) must stop the
iSave when the pressure is lower than
the minimum inlet pressure or higher
than the maximum pressure.