Execute Auto Adjustment

Auto adjustment aims to automatically adjust servo gain for servo unit according to the current
status of machine tool, and thus to optimize response.
In NK280B, auto adjustment for X-axis, Y-axis and Z-axis will be executed separately. Auto
adjustment will not be executed until the auto adjustment for last axis is done.
Due to the different brands of drivers, process of auto adjustment differs.

Set Station Address for Driver

Setting station address for driver is the prerequisite of data transmission among control system,
lambda controller and driver.
Set Station Address for YASKAWA Driver
The setting of station address for YASKAWA bus-type driver is done through combined actions
of rotary switch(S2) and toggle switch(S3).
To set station address for YASKAWA driver:
1. Optional: Modify setting of No.3 for S3.
Other numbers of S3 adopt factory settings.
Setting illustration for S3 is as shown in the following table:
No.
Illustration
1
Setting for communication speed.
• OFF: 4Mbps (M1)
• ON: 10Mbps (M2)
2
Setting for bytes transmitted.
• OFF: 17 bytes
• ON: 32 bytes
3
Setting for station address.
• OFF: actual address=40H+S2
• ON: actual address=50H+S2
Basic Commissioning
Factory Setting
ON
ON
OFF