Displaying the power module operating status

Use the
display power-supply
<Sysname> display power-supply
Power No.
------------------------------------------------
1
2
Table6-7 Command output
Field
Power No.
State
Description

Displaying the alarming thresholds of a card

Use the
display environment
thresholds of a card.
<Sysname> display environment
System temperature information (degree centigrade):
------------------------------------------------------------------------------
Slot
Sensor
Vent
Hotspot 1 28
0
Outflow 1 37
0
Hotspot 1 28
1
Inflow
1
Outflow 1 31
Table6-8 Command output
Field
System Temperature
information (degree centigrade)
sensor
Slot
Temperature
LowerLimit
WarningLimit
State
Description
Absent
Unknown
Normal
VAPEL-300AC
Description
Slot number of the power module.
Power module state:
Description for the power module.
Temperature LowerLimit WarningLimit AlarmLimit ShutdownLimit
0
0
0
1 28
0
0
Description
Temperature information (°C).
Temperature sensor:
Sensor position. For a sensor on the chassis for fan tray, this field
displays Vent.
Current temperature.
Lower temperature limit.
Warning temperature threshold.
command to display the power module operating status.
Normal—The power module is operating correctly.
Absent—The power module is not in position.
Fault—The power module has failed.
command to display the temperature information and alarming
120
53
65
50
53
Hotspot—Hotspot sensor.
Inflow—Air inlet sensor.
Outflow—Air outlet sensor.
65
255
255
57
255
80
255
57
255
60
255

Advertisement