Displaying the operational status of the fan

Use the display fan command to display the operational status of the fan.
<Sysname> display fan
Fan
1 State: Normal
Table 18 Output description
Field
Fan
1
State

Displaying the operational status of power modules

Use the display power-supply command to display the operational status of power supplies.
<Sysname> display power-supply
Power No.
------------------------------------------------
1
2
Table 19 Output description
Field
Power No.
State
Description

Displaying the alarming thresholds of a module

When the router is operating, too high a temperature and too low a temperature of a module affect
the normal operation of the router. When the temperature of a module exceeds 80°C (176°F) or
drops below 0°C (32°F), the system sends traps to prompt you to solve the problem.
Description
Operational status of the CF card:
Storage capacity of the CF card
Description
Number of the fan
The fan state:
State
Description
Normal
EMERSON-650AC
Absent
Unknown
Description
Power supply slot
The power supply state:
Description for the power supply
Absent—No CF card is present in the slot.
Fault—The CF card fails.
Normal—The CF card is operating correctly.
Normal—The fan is operating correctly.
Absent—The fan is not in position.
Fault—The fan fails.
Normal—The power supply is operating correctly.
Absent—The power supply is not in position.
Fault—The power supply fails.