Displaying The Operational Status Of The Fan; Displaying The Operational Status Of Power Supplies; Displaying The Alarming Thresholds Of A Module - H3C SR6604 Installation Manual

Hide thumbs Also See for SR6604:
Table of Contents

Advertisement

Field
Status:
Size:

Displaying the operational status of the fan

Use the display fan command to display the operational status of the fan.
<Sysname> display fan
Fan
1 State: Normal
Table 16 Output description
Field
Fan
1
State

Displaying the operational status of power supplies

Use the display power command to display the operational status of power supplies.
<Sysname> display power
Power
1 State: Absent
Power
2 State: Normal
Table 17 Output description
Field
Power
1
State

Displaying the alarming thresholds of a module

When the router is operating, too high a temperature and too low a temperature of a module affect the
normal operation of the router. When the temperature of a module exceeds 80°C (176°F) or drops below
0°C (32°F), the system sends traps to prompt you to solve the problem.
Follow these steps to display the alarming thresholds of a module:
Description
Operational status of the CF card:
Absent—No CF card is present in the slot.
Fault—The CF card fails.
Normal—The CF card is operating properly.
Storage capacity of the CF card
Description
Number of the fan
The fan state:
Normal—The fan is operating properly.
Absent—The fan is not in position.
Fault—The fan fails.
Description
Number of the power supply
The power supply state:
Normal—The power supply is operating properly.
Absent—The power supply is not in position.
Fault—The power supply fails.
59