Displaying The Operational Status Of The Fan; Displaying The Operational Status Of Power Modules; Displaying The Alarming Thresholds Of A Module - H3C SR6616 Installation Manual

Hide thumbs Also See for SR6616:
Table of Contents

Advertisement

Field
Status:
Size:

Displaying the operational status of the fan

Use the display fan command to display the operational status of the fan.
<Sysname> display fan
Fan
1 State: Normal
Table 18 Command output
Field
Fan
1
State

Displaying the operational status of power modules

Use the display power-supply command to display the operational status of power modules.
<Sysname> display power-supply
Power No.
------------------------------------------------
1
2
Table 19 Command output
Field
Power No.
State
Description

Displaying the alarming thresholds of a module

When the router is operating, too high a temperature and too low a temperature of a module affect
the normal operation of the router. When the temperature of a module exceeds 80°C (176°F) or
drops below 0°C (32°F), the system sends traps to prompt you to solve the problem.
Description
Operational status of the CF card:
Storage capacity of the CF card
Description
Number of the fan
The fan state:
State
Description
Absent
Unknown
Normal
VAPEL-300AC
Description
Power module slot
Power module state:
Description for the power module
Absent—No CF card is present in the slot.
Fault—The CF card has failed.
Normal—The CF card is operating correctly.
Normal—The fan is operating correctly.
Absent—The fan is not in position.
Fault—The fan has failed.
Normal—The power module is operating correctly.
Absent—The power module is not in position.
Fault—The power module has failed.
64

Advertisement

Table of Contents
loading