Installing An Mpu And A Switching Fabric Module; Installing An Mpu; Installing An Sfe-X1 Switching Fabric Module - H3C SR6600-X Series Manual

Hide thumbs Also See for SR6600-X Series:
Table of Contents

Advertisement

Figure2-8 Installing a power module

Installing an MPU and a switching fabric module

Installing an MPU

CAUTION:
The RUN LED flashes fast when the MPU is starting up. Do not install or remove the MPU during this
period to avoid hardware damage.
Before the installation, make sure the ejector levers of the MPU are outwards.
Slot 4 on the SR6616-X does not have a filler panel.
The installation procedures for the RSE-X2 and RSE-X3 MPUs are the same. The following example
uses the RSE-X2.
To install an MPU:
1.
Face the front of the router and locate the slot to be used.
2.
Loosen the captive screws on the filler panel in the slot, and then remove the filler panel.
Keep the removed filler panel for future use.
Skip this step if you install the MPU to slot 4 of an SR6616-X router.
3.
Insert the MPU slowly along the slide rails until it makes close contact with the backplane, and
then push the ejector levers inward to lock the MPU in position.
4.
Fasten the captive screws on the two sides of the MPU.
For the MPU LED description, see H3C SR6604-X/SR6608-X/SR6616-X Routers Hardware
Information and Specifications.
Figure2-9 Installing an MPU

Installing an SFE-X1 switching fabric module

On the SR6616-X, slot 6 must have an SFE-X1 switching fabric module installed.
Before the installation, make sure the ejector levers of the SFE-X1 are outwards.
15