Operating Power Module Failure; Symptom; Troubleshooting Flowchart; Solution - H3C S5560-EI Series Troubleshooting Manual

Hide thumbs Also See for S5560-EI Series:
Table of Contents

Advertisement

Operating power module failure

Symptom

An operating power module fails.

Troubleshooting flowchart

Figure 2 Troubleshooting operating power module failure

Solution

To resolve the problem:
1.
Identify the operating state of the power module.
[Sysname]display power
Slot 2:
PowerID State
1
2
If the power module is in Absent state, go to step 2. If the power module is in Fault state, go to
step 3.
2.
Remove and reinstall the power module to make sure the power module is installed securely. Then,
execute the display power command to verify that the power module has changed to Normal state.
If the power module remains in Absent state, replace the power module.
3.
When the power module is in Fault state, perform the following tasks:
Mode
Normal
--
Absent
--
Current(A)
Voltage(V)
--
--
--
--
7
Power(W)
--
--

Advertisement

Table of Contents
loading

Table of Contents