System software image file missing errors

Symptom
When none of the main, backup, and secure system software image files exists, the system displays
the following information at startup:
BootWare Validating...
Application program does not exist.
Please input BootWare password:
If you select 1 on the main BootWare menu, the system displays the following information:
Starting to get the main application file--cfa0:/main.bin!
The main application file does not exist--cfa0:/main.bin!
Starting to get the backup application file--cfa0:/backup.bin!
The backup application file does not exist--cfa0:/backup.bin!
Starting to get the secure application file--cfa0:/secure.bin!
The secure application file does not exist--cfa0:/secure.bin!
Booting App fails!
The name of the main, backup, and secure system software image files vary by user settings.
A possible reason for the errors is that the main, backup, and secure system software image files
have been deleted or damaged.
Solution
To solve this problem:
1.
Download the application package again or set the file attributes in the BootWare file list.
2.
If the problem persists, contact H3C Support.