Cut the two cables the same length and insert them into the connector. Ensure
that each cable has been inserted all the way tot he end of the cover. (Refer to
Figure 2-38: Attaching the Cables to the Connector, Pg 78.)
ICT Cable
*Remove insulation from wire before inserting into connector.

Figure 2-38: Attaching the Cables to the Connector

Lightly hold the connector with the pliers. In this case, make sure that the crimping
portion is held between the lower portion of the jaws of the pliers. (Refer to Figure
2-39: Holding the Connector with the Pliers, Pg 78.)

Figure 2-39: Holding the Connector with the Pliers

Squeeze the pliers to crimp the cables. If the cover is loose, press the cover again
with the pliers. Be careful when squeezing the handles of the pliers as excessive
pressure may cause damage to the connectors.
a)
After crimping the leads into the special connectors, insert them into the
appropriate socket in the KSU, pushing firmly until the connector snaps
securely into position.
b)
To disconnect the plug from the socket, grasp it firmly using a pair of pliers
and pull while holding the unit in place. Do not pull on the wires directly.
c)
Do not reuse the plugs once they have been clinched as this may result in a
poor connection.
Adapter Cable
Core Diameter
Insulation Diameter
0.40 mm
0.66 mm
0.50 mm
0.80 mm
0.65 mm*
1.20 mm
Installation Manual, Chapter 2 – KSU Installation