Units With Casters: Fasten Both Caster Stops To The Floor - Henny Penny FlexFusion Platinum Installation Manual

Electric combi team
Table of Contents

Advertisement

Requirements The floor must support the weight of the unit

5.5.2 Units with casters: Fasten both caster stops to the floor

Prerequisite Floor capable of accommodating the weight of the unit
A
a
d
c
Image: A: Position of floor plate; B: floor plate glued to the floor
a Cap nut
b Holding plate
c Upright bolt
The floor must be clean and suitable for the manner of fastening
Unit set up and aligned in accordance with the planning drawing
1. Insert the floor plate from the fastener set into the holding plate as
shown in the drawing.
2. Screw on the cap nuts hand-tight.
3. Align the floor fasteners in position 1-1 or 2-2 on the unit leg as
shown in the drawing and mark the floor.
4. Screw on the cap nuts and remove the holding plate from the floor
plate.
5. Fasten the floor plates to the floor with the enclosed adhesive.
Follow the instructions of the adhesive manufacturer.
Apply the adhesive in accordance with the manufacturer's
instructions.
Observe the drying time in the manufacturer's instructions.
6. Place the holding plate on the floor plates and fasten in place with
cap nuts.
7. Fill out the start-up operation report.
Floor must be clean and suitable for the manner fastening
1. Place the unit into the final position.
2. Place the caster stops in the correct position at the rear casters.
3. Mark the position of the caster stops on the floor.
4. Remove the unit.
5. Using the required hardware depending on the floor, fasten the
caster stops to the floor.
6. Follow the manufacturer´s instructions regarding the hardware.
Installation instructions
Installing the unit
B
e
b
d Floor plate
e Unit leg
23