Advanced Energy
Table F‑2. Converter box and analog box UPP commands (Continued)
Parameter
Change IP
<AA>ip<VAL>
address of
PROFINET
module
Read IP range
<AA>ip?
Read streaming
<AA>sm
mode
Change
<AA>sm<VAL>
streaming mode
Read streaming
<AA>sm?
range
57010228-00C
Command
8-digit hexadecimal ASCII. Use the re
command to restart the pyrometer and activate
the new address.
For example, to change the PROFINET IP
address to 192.168.0.10, convert the values
to hexadecimal (C0.A8.01.0A) and send the
command, <AA>ip<C0A8010A>.
The converter box responds with the 16-digit
hexadecimal address range.
The converter box responds with the streaming
mode (1-digit, ASCII decimal).
Sets a new streaming mode (1 digit, ASCII
decimal). Valid values are: 0, 1, 2, or 3.
The converter box responds with the streaming
range (2 digit, ASCII decimal).
UPP Commands
Impac
Description
XXXXXXXXYYYYYYYY
XXXXXXXX: Start
YYYYYYYY: End
0 = Streaming off
1 = Streaming on, USB active
2 = Streaming on, RS interface active
3 = Streaming on, USB and RS interfaces
active
0 = Streaming off
1 = Streaming on, USB active
2 = Streaming on, RS interface active
3 = Streaming on, USB and RS interfaces
active
01 = Standard
03 = For versions with an external RS
module
®
Series 600 Pyrometer
F‑10