Connecting the unit
6
Making the water connection
6.4.2
Prerequisite
28
➢ Required water pressure available
➢ Pressure-resistant hoses suitable for drinking water available
a) Connect the hoses to the respective water connection fittings.
b) Open the water taps and flush the hoses.
c) Insert a dirt filter into the hard and soft water connections.
d) Connect hoses to the unit.
e) Open the water taps and check the threaded fittings for leaks.

Connect only to soft water

If only a soft water connection is available at the installation site, the hard
water connection and the soft water connection must be connected by
means of a T-piece.
Only connection of soft water
a Soft water tap
b Backflow preventer
c Hose - soft water
d Connection - soft water
➢ Hose connected to soft water fitting connection
a) Insert a dirt filter into the hard and soft water connections.
b) Connect the T-piece with seals to soft water fitting connection.
c) Connect hose with seal to the T-piece.
d) Open the connection of soft water fitting and check fittings for leakage.
e) Fill out the commissioning report at the end of this manual.