Wiring between PSU AC IN and CQD-2312 AC
Cut and strip the 2-core cabtyre cable off as follows.
Table. List of cutting / stripping length of the cable between PSU AC IN and CQD-2312 AC
Destination
Insulation
strip
For
length
[mm]
12
PSU AC IN
* Tolerance: +/- 10%
Wiring between UPS AC IN and CQD-2312 AC
Cut and strip the 2-core cabtyre cable off as follows.
Crimp the ring terminal to the conductor with white insulation of CQD-2312 side.
Table. List of cutting / stripping length of wires between UPS AC IN and CQD-2312 AC
Destination
Insulatio
n strip
For
length
[mm]
8
UPS AC IN
* Tolerance: +/- 10%
Name and
Length
Sheath
Name
strip
Cutting length
length
[mm]
[mm]
VCT-2C 5.5sq
150
550
Name and
Length
Sheath
Name
strip
Cutting Length
length
[mm]
[mm]
VCT-3C 3.5sq
100
1000
4-463
Relay terminal block
Sheath
Insulation
strip
strip
length
length
[mm]
[mm]
100
12
Relay terminal block
Sheath
Insulatio
strip
n strip
length
length
[mm]
[mm]
200
12
Chapter 4 Replacement procedure
Relay
terminal
block
AC
Relay
terminal
block
AC

Hide quick links: