JRC JMR-92 Series Field Service Manual page 997

Marine radar equipment, ecdis conning display
Table of Contents

Advertisement

8.2.28
JAN-7202 General System Diagrams
Stand alone type
AIS
(IEC61162-2)
GYRO COMPASS
(IEC61162-2)
No.1 DGPS
(IEC61162-1)
SDME
(IEC61162-1)
BNWAS
(Dry Contact)
AIS
150/250V TTYCSLA-4
(IEC61162-2)
150/250V TTYCSLA-1
GYRO COMPASS
(IEC61162-2)
No.1 DGPS
150/250V TTYCSLA-1
(IEC61162-1)
150/250V TTYCSLA-1
SDME
(IEC61162-1)
BNWAS
150/250V TTYCSLA-1
(Dry Contact)
Transitional Source of
0.6/1kV DPYCYS-16
Emergency Electric Power
24VDC/Max300W
(For System Backup)
0.6/1kV DPYCY-6
Ship's Main
AC220V 1PH/Max240VA
NOTE: ELIMINATING THE INTERFERENCE ON FREQUENCIES USED FOR MARINE COMMUNICATIONS AND
     NAVIGATION DUE TO OPERATION OF THE RADAR,
ALL CABLES OF THE RADAR ARE TO BE RUN AWAY FROM THE CABLES OF RADIO EQUIPMENT.
(ex. RADIOTELEPHONE, COMMUNICATIONS RECEIVER and DIRECTION FINDER. etc..)
ESPECIALLY INTER-WIRING CABLES BETWEEN SCANNER UNIT AND DISPLAY UNIT OF THE RADAR
SHOULD NOT BE RUN PARALLEL WITH THE CABLES OF RADIO EQUIPMENT.
Chapter 8 Appdendix
Keyboard Operation Unit
150/250V TTYCSLA-4
150/250V TTYCSLA-1
150/250V TTYCSLA-1
150/250V TTYCSLA-1
150/250V TTYCSLA-1
Inner wiring
24VDC/Max0.4A
(For LAN Unit)
Inner wiring
24VDC/Max2A
(For Junction Box:SLC)
CQD-2312
Relay
Terminal
CWA-245 19inch Display Unit Mount Kit
General System Diagram of JAN-7202 CONNING
8-86
NWZ-207 or NWZ-214
19inch Monitor Unit
NCE-5625
NCE-5605
Trackball Operation Unit
(Option)
W64:7ZCNA4187(0.40m)
NQA-2443
CAT-5 LAN Cable
Sensor LAN
Switch Unit
(Option)
CAT-5 LAN Cable
NQE-1143
Junction Box
(Option)
Inner wiring
24VDC
Inner wiring
AC220V 1PH
(Option)
NDC-1590
Central Control Unit
NBD-913
Power Supply Unit

Hide quick links: