14-1. Update the MFD application. (All Licence)
Update the MFD application to the latest version by referring the following:
-
14-2. Setup Own Task Station, Network, Serial port, Contact output, etc. of the
CCU. (All licence)
Installation settings consist of Common setting items and Equipment-specific
setting items. Common setting items can be synchronized with the system
automatically via SLC.
Equipment-specific setting items cannot be synchronized with the system,
therefore they need to setup manually.
14-2-1. Common setting items
Confirm that SLC is already started up and LAN connection is available.
Start the display unit, click [Menu] – [Code Input] button and input password
"0009". When selected [Menu] – [Service] – [Installation], the common setting
items are synchronized with the system automatically.
For the details of common setting items, refer to "Installation Manual 4.43 List of
Common Setting Items".
In order to synchronize common setting items, make sure that SLC is already
started up and LAN connection is available, before starting the display unit.
14-2-2. Equipment-specific setting items
- Settings for Own Task Station
Own Task Station setting is placed on the upper side of [System Configuration]
- [Subsystem Installation] dialog.
Set up Own Task Station number. And make sure that Own Task Station
number is same as Device Installation settings as below.
Do not set a duplicated Task Station number and a duplicated IP Address.
Otherwise, unintended operation is performed, e.g. sensor data cannot be
received.
Chapter 4 Replacement procedure
Field Service Manual 5.1 Updating the Software
4-346