JRC JMR-92 Series Field Service Manual page 987

Marine radar equipment, ecdis conning display
Table of Contents

Advertisement

8.2.23
JMR-7282-S General System Diagrams
Stand alone type
NKE-2632
Scanner Unit
AIS
(IEC61162-2)
GYRO COMPASS
(IEC61162-2)
No.1 DGPS
(IEC61162-1)
SDME
(IEC61162-1)
BNWAS
(Dry Contact)
Transitional Source of
Emergency Electric Power
24VDC/Max300W
Ship's Main
AC220V 1PH/Max1400VA
NOTE: ELIMINATING THE INTERFERENCE ON FREQUENCIES USED FOR MARINE COMMUNICATIONS AND
     NAVIGATION DUE TO OPERATION OF THE RADAR,
ALL CABLES OF THE RADAR ARE TO BE RUN AWAY FROM THE CABLES OF RADIO EQUIPMENT.
(ex. RADIOTELEPHONE, COMMUNICATIONS RECEIVER and DIRECTION FINDER. etc..)
ESPECIALLY INTER-WIRING CABLES BETWEEN SCANNER UNIT AND DISPLAY UNIT OF THE RADAR
SHOULD NOT BE RUN PARALLEL WITH THE CABLES OF RADIO EQUIPMENT.
Chapter 8 Appdendix
Circuit Breaker
(Dock Supply)
(5A)
AIS
150/250V TTYCSLA-4
(IEC61162-2)
150/250V TTYCSLA-1
GYRO COMPASS
(IEC61162-2)
No.1 DGPS
150/250V TTYCSLA-1
(IEC61162-1)
150/250V TTYCSLA-1
SDME
(IEC61162-1)
BNWAS
150/250V TTYCSLA-1
(Dry Contact)
Inner wiring
24VDC/Max0.4A
(For LAN Unit)
2695110056 14 Cores Composite Cable
150/250V TTYCSLA-4
150/250V TTYCSLA-1
150/250V TTYCSLA-1
150/250V TTYCSLA-1
150/250V TTYCSLA-1
Inner wiring
24VDC/Max2A
(For Junction Box:SLC)
0.6/1kV DPYCYS-16
0.6/1kV DPYCY-6
8-76
0.6/1kV DPYCYS-1.5
Ship's Main AC100V / 220V
For Heater
NCE-5625
Keyboard Operation Unit
(Option)
W64:7ZCNA4187(0.40m)
NQA-2443
CAT-5 LAN Cable
Sensor LAN
Switch Unit
(Option)
CAT-5 LAN Cable
CML-836AC
W841:7ZCNA4164(1m)
NQE-1143
Junction Box
(Option)
CML-836AC
W851:7ZCNA4158(0.85m)
Inner wiring
24VDC
Inner wiring
AC220V 1PH
CQD-2312
Relay
Terminal
CWA-245 19inch Display Unit Mount Kit
General System Diagram of JMR-7282-S RADAR
Option
Upper Deck
Lower Deck
NWZ-207 or NWZ-214
19inch Monitor Unit
NCE-5605
Trackball Operation Unit
NDC-1590
Central Control Unit
NBD-913
Power Supply Unit

Hide quick links: