6.5.2 Changing the subsystem configuration
Set the following items in the "Subsystem Installation" dialog.
If the presence/absence of the equipment is set in this dialog, the menu display/hide and configuration
contents relating to the equipment change according to the setting contents.
Setting item
Own Task Station
Select the Task Station number of the equipment from
the combo box.
Select from the task stations that were set in Task
Stations 1 to 8 of Device Installation.
Select installation/non-installation of the USB OPU
(Operation Unit) by using the [USB OPU] check box.
When the unit is installed, select the installation
contents in the [USB OPU] combo box.
Memo
When OPU is installed, the OPU active/inactive
monitoring is performed. When there is no response,
the following alert is displayed and OPU is restarted.
OPU: OPU-USB(Communication error)
Keyboard: OPA-OPB(Communication error)
Select the installation/non-installation of Serial
OPU (Operation Unit) by using the [Serial OPU]
check box. When OPU is installed, select the
installation contents in the [Serial OPU] combo
box.
Memo
When OPU is installed, the OPU active/inactive
monitoring is performed. When there is no response,
the following alert is displayed and OPU is restarted.
OPU: OPU-Serial(Communication error)
Keyboard: OPA-OPB(Communication error)
Junction Box
Select installed/not installed of junction boxes 1 to 8
from the [Junction Box 1 ~ 8] check boxes.
In the combo box for selecting a Task Station, select
the equipment that is directly connected to Radar I/F
or Gyro I/F of the junction box.
Select the equipment to be installed in the Junction
Box that was selected from [Junction Box 1 ~ 8] check
boxes.
When SLC is selected from the combo box, select
installed/not installed of AOC with the [AOC] check
box.
Description of setting
6-15
Chapter 6 Connection to External Navigation Equipment
Setting value
Task Station 1 ~ Task Station 8
Installation/non-installation of
the unit
Absent: Clear
Present: Select
Installation contents
No keyboard operation unit
(optional):
Select Trackball.
Keyboard operation unit
(optional):
Select Trackball + Keyboard.
Installation/non-installation
Non-installation: Clear
Installation: Select
Installation contents
No keyboard operation unit
(optional):
Select Trackball.
Keyboard operation unit
(optional):
Select Trackball + Keyboard.
Not installed: Clear.
Installed: Select.
Equipment that is assigned to
any of Task Stations 1 to 8 of
Device Installation
None
SLC 1 to 8(Main)
SLC 1 to 8(Sub)
ALC 1 to 8
RIF
GIF
RIF + GIF
Not installed: Clear.
Installed: Select.