JRC JMR-92 Series Field Service Manual page 446

Marine radar equipment, ecdis conning display
Table of Contents

Advertisement

M10 ボルト
Remove two
bolts (M10)
(2 箇所)
Motor
モータ
Port side
左舷側
Step 3
Operation check
After completing the replacement work, turn On the safety switch and follow the steps below to
check the operation.
1.
Turn On the Display unit. Start transmission and check that the radar image appears
without error. Check that the motor does not make any abnormal sound when it starts to
rotate, while it is rotating, or when it stops.
2.
Open the service engineer menu to initialize the motor rotation time.
This completes motor replacement.
Chapter 4 Replacement procedure
モータ
Motor driver
circuit
ドライバー部
モータケーブル
Motor cable
connector
4-226
コネクタ

Hide quick links:

Advertisement

Table of Contents
loading