JRC JMR-92 Series Field Service Manual page 802

Marine radar equipment, ecdis conning display
Table of Contents

Advertisement

Note
Do not select the same Task Station number of Own Task Station among multiple devices. If
the same Task Station number is selected among multiple devices, unintended operation is
performed.
When performing radar overlay without installing interswitch, do not forget to check Device
Installation systems RADAR1 and RADAR2 (when two radar systems are available). When
interswitch is installed and available for use, radar overlay can be performed regardless of the
setting of RADAR1 and RADAR2. For the setting of interswitch, refer to "4.16 Setting
Interswitch".
Setting example
The following diagram shows the setting example of [Own Task Station] and [Device Installation] when
the subsystem is configured as follows:
No.1 RADAR (S band radar) as Task Station 1
No.2 RADAR (X band radar) as Task Station 2
No.1 ECDIS as Task Station 3
No.2 ECDIS as Task Station 4
Conning as Task Station 5
6.5.3 Saving subsystem configuration changes
1
Click on the [Set] button in the "Subsystem Installation" dialog.
A dialog is displayed prompting confirmation of saving the configuration changes.
6-17