Sub-Screen
Second Level
Sub-screen
COM2 Console
Redirection
COM2 Console
Redirection
settings
www.kontron.com
Further Sub-Screens/Description
Putty Keypad
Select function key and key pad on putty.
[VT100, LINUX, XTERMR6, SCO, ESCN, VT400]
Console redirection via COMe module's COM2.
If redirection is enabled then the port settings such as Terminal
type, Bits per second, Data bits, Parity etc. can be adjusted here.
Note: On-module COM ports do not support flow control.
[Enabled, Disabled]
The settings specify how the host computer and the remote
computer (which the user is using) will exchange data. Both
computers should have the same or compatible settings.
Terminal Type
Bits per Second
Data Bits
Parity
Stop Bits
COMe-bID7 User Guide Rev. 1.2
Emulation:
ANSI: Extended ASCII character
set
VT100: ASCII character set
VT100+: Extend VT100 to support
color, function keys etc.
VT-UTF8: uses UTF8 encoding to
map
Unicode chars onto 1 or more
bytes.
[VT100, VT100+, VT-UTF8, ANSI]
Selects the serial port
transmission speed. The sped
must be matched on the other
side. Long or noisy lines may
require lower speeds.
[9600, 19200, 38400, 57600,
115200]
Data Bits
[7, 8]
A parity bit can be sent with the
data bits to detect transmission
errors.
Even: parity bit is 0 if the num of
1's in the data bits is even.
Odd: parity bit is 0 if the num of
1's in the data bits is odd.
Mark: parity bit is always 1.
Space: Parity bit is always 0.
Mark and Space Parity do not
allow error detection.
[None , Even, Odd, Mark, Space]
Stop bits indicate the end of a
serial data packet. (A start bit
indicates the beginning).
The standard setting is 1 stop bit.
Communication with slow
devices may require more than 1
stop bit.
[1, 2]