Sub-Screen
Second Level
Sub-screen
www.kontron.com
Further Sub-Screens/Description
Emulation:
Terminal
Type
ANSI: Extended ASCII character set
VT100: ASCII character set
VT100+: Extend VT100 to support color,
function keys etc.
VT-UTF8: uses UTF8 encoding to map
Unicode chars onto 1 or more bytes.
[VT100, VT100+, VT-UTF8, ANSI]
Bits per
Selects the serial port transmission speed. The
Second
sped must be matched on the other side. Long
or noisy lines may require lower speeds.
[9600, 19200, 38400, 57600, 115200]
Data Bits
Data Bits
[7, 8]
Parity
A parity bit can be sent with the data bits to
detect transmission errors.
Even: parity bit is 0 if the num of
Odd: parity bit is 0 if the num of
Mark: parity bit is always 1.
Space: Parity bit is always 0.
Mark and Space Parity do not allow error
detection. [None , Even, Odd, Mark, Space]
Stop Bits
Stop bits indicate the end of a serial data
packet. (A start bit indicates the beginning).
The standard setting is 1 stop bit.
Communication with slow devices may require
more than 1 stop bit.
[1, 2]
Flow Control
Flow control can prevent data loss from buffer
overflow. When sending data, if the receiving
buffers are full, a 'stop' signal can be sent to
stop the data flow. Once the buffers are empty,
a 'start' signal can be sent to re-start the flow.
Hardware flow control uses two wires to send
start/stop signals.
[None, hardware RTS/CTS]
VT-UTF8
Enables VT-UTF8 combination key support for
Combo Key
ANSI/VT100 terminals
Support
[Enabled, Disabled]
Recorder
If enabled, only text will be sent. This is to
Mode
capture terminal data.
[Enabled, Disabled]
Resolution
Enables or disables extended terminal
100x31
resolution.
[Enabled, Disabled]
Legacy OS
On legacy OS, the number of row and columns
Redirection
supported redirection
Resolution
[80x24, 80x25]
COMe-bID7 User Guide Rev. 1.2
1's in the data bits is even.
1's in the data bits is odd.