Installation instructions

3.7.2 Checking and setting the pre-rinse flow

3.8 Installation and connection of auxiliary equipment and options

The various options normally place no specific requirement on the installation.
WD-40BRE
Connect hoses to the nozzles in the pre-rinse. Allow the hoses to run into
a vessel that holds 6-7 litres.
Start the machine in accordance with THE USER INSTRUCTIONS and let
it run for 1 minute. Then stop the machine.
Measure the volume of water in the vessel. The flow should normally be 2
litres per minute. Always check the flow diagram supplied to see which flow
applies for the machine. Where necessary, adjust the flow using the ball
valve which is located next to the solenoid valve Y01.
Repeat the procedure until the correct flow has been achieved.
Remove the hoses.
Once the machine is in place and has been adjusted horizontally and
vertically, the auxiliary equipment can be fitted.
The machine can be equipped with a number of options. Check what your
machine is equipped with, which depends on the model, machine type and
country.