Installation instructions
3.7 Checking and setting the flow
3.7.1 Checking and setting the final rinse flow
The water flow is set in the factory but should be checked after the machine has
been installed.
"Diagnosis" tab
In order to access "Diagnosis", the user must log in with access level S1. The
password for S1 is "wd"
•
Prepare the machine for use in accordance with THE USER
INSTRUCTIONS.
•
Start feed.
•
Tape over the photocell on the infeed and wait until the final rinse starts.
•
Go to Menu - Change service settings - a login page will be displayed
where you log in.
•
Select the "Machine status" tab, and under this select the "Diagnosis" tab.
•
Scroll down to the text "DI16 Card 1 BV02 Water meter". The final rinse
flow is displayed in litres/min.
•
Adjust the flow using the needle valve located next to the water meter. The
flow, which depends on the size of the machine, should be approximately
2.8-4 litres/min. The exact flow can be found on the machine's flow diagram
which is in the electrical cabinet.
•
Exit the "Diagnosis" tab using the home key. Remove the tape from the
photocell.
WD-40BRE
17