Checking And Setting The Final Rinse Flow - Wexiodisk WD-B 500 Installation And User Manual

Flight-type dishwasher
Table of Contents

Advertisement

Installation

3.8 Checking and setting the final rinse flow

Control panel functions for checking the final rinse flow
1.
2.
3.
4.
The final rinse flow is set in the factory, but should be checked after the machine
has been installed.
WD-B 500 - WD-B 900
4
Button for the feed
Button for the diagnostics function
Button for switching between diagnostic messages
Display for showing texts
Prepare the machine for use in accordance with the INSTRUCTIONS FOR
USE.
Start the feed by pressing button (1).
Tape over the photocell on the infeed and wait until the final rinse starts.
Press and hold button (2) until the display (4) shows a menu with the fol-
lowing groups: SETPOINTS - DIAGNOSIS - RELAY TEST - STATISTICS
- TIME & DATE - LANGUAGE - OTHER.
Select DIAGNOSIS using button (2).
Press button (3) to display the first message and use button (3) to scroll
through the messages until DI16 CARD1 BV02 FLOW SENSOR is dis-
played. The final rinse flow is displayed in litres/min.
Adjust the flow using the reducing valve which is located next to the water
meter. The flow, which depends on the size of the machine, should be
around 4-5 litres/min. The exact flow can be found on the machine's flow
diagram which is in the electrical cabinet.
Exit the diagnostics function by pressing button (2). Press and hold the but-
ton until the corresponding LED goes out. Remove the tape from the pho-
tocell.
19
1
2
3
WDB_09
Rev. 4.0 (201208)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wd-b 900

Table of Contents