Power Supply; Water Connection, Regardless Of Any Options; Ventilation - Wexiodisk WD-40BRE Installation And User Manual

Tray dishwasher
Table of Contents

Advertisement

Installation instructions

3.6.1 Power supply

Information about electrical connections is available on the machine's wiring
diagram which is provided on delivery. Store the diagrams in the plastic pocket,
located in the electrical cabinet, even after installation.
After completing the installation, switch on the main switch and all circuit
breakers.

3.6.2 Water connection, regardless of any options

Connect the cold and hot water pipes according to the labels by the connection
points (6, 7). If the machine is connected with a hose, this should be steel braided
and have an internal diameter of at least 12 mm.
The hot water connection on the machine is fitted with a filter.
The cold water connection on the machine is fitted with a filter, non-return valve
and Break tank.

3.6.3 Ventilation

The machine has a ventilation connection (1) on the top of the steam hood at the
infeed opening. This is where the connection is made with the ventilation duct.
The location and size of the connection are shown on the installation diagram.
The machine's heat load for the room is stipulated in TECHNICAL
SPECIFICATIONS.
WD-40BRE
The machine is designed for quick electrical connection and is connected
to (2) or (8).
The machine must be connected to a lockable main switch. This should be
placed on a wall, well-protected from water and from the steam which
escapes when the machine is opened.
The machine has a built-in main switch. Rating data is given on the rating
plates, which are located on the end of the outfeed and in the electrical
cabinet. Electrical data is also shown on the machine's wiring diagram. The
installation diagram shows the location of the electrical connection
It is important that the electrical connection is checked so that it is certain
that the live and neutral wires are correctly connected and not swapped
over. It is also important to check at the same time that the earthing system
connection is correct and sufficient so that the machine's electrical and
personal security system is not compromised.
A shut-off cock must be installed on the incoming lines.
The machine is equipped with a break-tank including booster pump as
standard to obtain the correct flow of water to the machine. The required
water
flow
and
pressure
SPECIFICATIONS.
15
can
be
found
in
Rev. (202303)
the
TECHNICAL

Advertisement

Table of Contents