Figure B-2 Preparing an OT terminal
(1) Cable
(4) Hydraulic pliers
B.3 Preparing a PV Input Power Cable
● Use the delivered Staubli MC4 EVO2 positive and negative metal terminals and
● Use professional tools to prepare cables.
● Cables with high rigidity, such as armored cables, are not recommended.
● Before assembling connectors, label the cable polarities correctly to ensure
● A PV-CZM-41100 crimping tool is recommended.
● Use the wrench shown in the figure to tighten the locking nut. When the
● After crimping the positive and negative metal terminals, pull the PV input
● Insert the crimped metal terminals of the positive and negative power cables
Issue 03 (2022-10-28)
CA UTION
connectors. Using incompatible positive and negative metal terminals and
connectors may result in serious consequences. The caused device damage is
not covered under any warranty or service agreement.
NO TICE
correct cable connections.
wrench slips during the tightening, it indicates that the locking nut has been
tightened.
power cables to ensure that they are connected securely.
into the appropriate positive and negative connectors. Then pull the PV input
power cables to ensure that they are connected securely.
Copyright © Huawei Digital Power Technologies Co., Ltd.
(2) OT terminal
(5) Heat gun
B Preparing the Cable and Terminal
(3) Heat shrink tubing
163