Monitoring The System Using Sun Advanced Lights Out Manager; Table 2-6 What Alom Monitors - Sun Microsystems Sun Fire V440 Diagnostics And Troubleshooting Manual

Hide thumbs Also See for Sun Fire V440:
Table of Contents

Advertisement

Monitoring the System Using Sun Advanced
Lights Out Manager
Sun Advanced Lights Out Manager (ALOM) enables you to monitor and control
your server over a serial port or a network interface. The ALOM system controller
provides a command-line interface that enables you to administer the server from
remote locations. This may be especially useful when servers are geographically
distributed or physically inaccessible.
ALOM also lets you remotely access the system console and run diagnostics (like
POST) that would otherwise require physical proximity to the server's serial port.
ALOM can send email notification of hardware failures or other server events.
The ALOM system controller runs independently, and uses standby power from the
server. Therefore, ALOM firmware and software continue to be effective when the
server operating system goes offline, or when power to the server itself is turned off.
ALOM lets you monitor the following on the Sun Fire V440 server.
What
ALOM
TABLE 2-6
Item Monitored
Disk drives
Fans and fan trays
CPU/memory
modules
Operating system
status
Power supplies
System temperature
Server front panel
User sessions
For instructions on using ALOM to monitor a Sun Fire V440 system, see "How to
Monitor the System Using Sun Advanced Lights Out Manager" on page 79.
Monitors
What ALOM Reveals
Whether each slot has a drive present, and whether the drive
reports OK status
Fan speed and whether the fan trays report OK status
The presence of a CPU/memory module and the
temperature measured at each CPU, as well as any thermal
warning
Whether the operating system is running, stopped,
initializing, or in some other state
Whether each bay has a power supply present, and whether
the power supply reports OK status
Ambient and CPU core temperatures as measured at several
locations in the system, as well as any thermal warning
System control keyswitch position and status of LEDs
Which users are logged in to ALOM, and via which
connections
Command to Type
showenvironment
showenvironment
showenvironment
showplatform
showenvironment
showenvironment
showenvironment
showusers
Chapter 2 Diagnostics and the Boot Process
35

Advertisement

Table of Contents
loading