consolehistory run -v Command Output (Continued)
CODE EXAMPLE 7-7
May 9 14:52:57 Sun-SFV440-a rmclomv: Keyswitch Position has changed to Unknown
state.
May
9 14:52:58 Sun-SFV440-a rmclomv: NOTICE: keyswitch change event - state =
LOCKED
May
9 14:52:58 Sun-SFV440-a rmclomv: KeySwitch Position has changed to Locked
State.
May
9 14:53:00 Sun-SFV440-a rmclomv: NOTICE: keyswitch change event - state =
NORMAL
May 9 14:53:01 Sun-SFV440-a rmclomv: KeySwitch Position has changed to On State.
sc>
3. Examine the ALOM boot log. Type:
sc> consolehistory boot -v
The ALOM boot log contains boot messages from POST, OpenBoot firmware, and
Solaris software from the server's most recent reset. When examining the output to
identify a problem, check for error messages from POST and OpenBoot Diagnostics
tests.
CODE EXAMPLE 7-8
error messages. See "What POST Error Messages Tell You" on page 11 for a sample
POST error message and more information about POST error messages.
consolehistory boot -v Command Output
CODE EXAMPLE 7-8
(Boot Messages From POST)
Keyswitch set to diagnostic position.
@(#)OBP 4.10.3 2003/05/02 20:25 Sun Fire V440
Clearing TLBs
Power-On Reset
Executing Power On SelfTest
0>@(#) Sun Fire[TM] V440 POST 4.10.3 2003/05/04 22:08
/export/work/staff/firmware_re/post/post-build-
4.10.3/Fiesta/chalupa/integrated
0>Hard Powerup RST thru SW
0>CPUs present in system: 0 1
0>OBP->POST Call with %o0=00000000.01012000.
0>Diag level set to MIN.
0>MFG scrpt mode set NORM
0>I/O port set to TTYA.
134
Sun Fire V440 Server Diagnostics and Troubleshooting Guide • July 2003
shows the boot messages from POST. Note that POST returned no