Sun Microsystems Sun Fire V440 Diagnostics And Troubleshooting Manual page 164

Hide thumbs Also See for Sun Fire V440:
Table of Contents

Advertisement

3. Examine the ALOM boot log. Type:
sc> consolehistory boot -v
The ALOM boot log contains boot messages from POST, OpenBoot firmware, and
Solaris software from the server's most recent reset. When examining the output to
identify a problem, check for error messages from POST and OpenBoot Diagnostics
tests.
CODE EXAMPLE 7-21
no error messages. See "What POST Error Messages Tell You" on page 11 for a
sample POST error message and more information about POST error messages.
consolehistory boot -v Command Output (Boot Messages From POST)
CODE EXAMPLE 7-21
Keyswitch set to diagnostic position.
@(#)OBP 4.10.3 2003/05/02 20:25 Sun Fire V440
Clearing TLBs
Power-On Reset
Executing Power On SelfTest
0>@(#) Sun Fire[TM] V440 POST 4.10.3 2003/05/04 22:08
/export/work/staff/firmware_re/post/post-build-
4.10.3/Fiesta/chalupa/integrated
0>Hard Powerup RST thru SW
0>CPUs present in system: 0 1
0>OBP->POST Call with %o0=00000000.01012000.
0>Diag level set to MIN.
0>MFG scrpt mode set NORM
0>I/O port set to TTYA.
0>
0>Start selftest...
1>Print Mem Config
1>Caches : Icache is ON, Dcache is ON, Wcache is ON, Pcache is ON.
1>Memory interleave set to 0
1>
Bank 0 1024MB : 00000010.00000000 -> 00000010.40000000.
1>
Bank 2 1024MB : 00000012.00000000 -> 00000012.40000000.
0>Print Mem Config
0>Caches : Icache is ON, Dcache is ON, Wcache is ON, Pcache is ON.
0>Memory interleave set to 0
0>
Bank 0 1024MB : 00000000.00000000 -> 00000000.40000000.
0>
Bank 2 1024MB : 00000002.00000000 -> 00000002.40000000.
0>INFO:
0>
POST Passed all devices.
0>
0>POST: Return to OBP.
146
Sun Fire V440 Server Diagnostics and Troubleshooting Guide • July 2003
shows the boot messages from POST. Note that POST returned