What OpenBoot Diagnostics Error Messages Tell You
OpenBoot Diagnostics error messages are reported in a tabular format that contains
a short summary of the problem, the hardware device affected, the subtest that
failed, and other diagnostic information.
OpenBoot Diagnostics error message, one that suggests a failure of the IDE
controller.
OpenBoot Diagnostics Error Message
CODE EXAMPLE 2-2
Testing /pci@1e,600000/ide@d
ERROR
: IDE device did not reset, busy bit not set
DEVICE
: /pci@1e,600000/ide@d
DEVICE
: /pci@1e,600000/ide@d
ex MACHINE : Sun Fire V440
SERIAL# : 51994289
DATE
: 10/17/2002 20:17:43
CONTR0LS: diag-level=min test-args=
Error: /pci@1e,600000/ide@d selftest failed, return code = 1
Selftest at /pci@1e,600000/ide@d (errors=1) ........................... failed
2
I
C Bus Device Tests
The
i2c@0,320
monitoring and control devices connected to the Sun Fire V440 server's Inter-
Integrated Circuit (I
Error and status messages from the
the hardware addresses of I
Testing /pci@1e,600000/isa@7/i2c@0,320/dimm-spd@0,b6
The I
example, the address is
address b6 on segment 0 of the I
To decode this device address, see "Reference for Decoding I
Messages" on page 49. Using
corresponds to DIMM 0 on CPU/memory module 0. If the
report an error against
20
Sun Fire V440 Server Diagnostics and Troubleshooting Guide • July 2003
OpenBoot Diagnostics test examines and reports on environmental
2
C) bus.
2
C device address is given at the very end of the hardware path. In this
0,b6
dimm-spd@0,b6
CODE EXAMPLE 2-2
GMT
OpenBoot Diagnostics test include
i2c@0,320
2
C bus devices.
, which indicates a device located at hexadecimal
2
C bus.
, you can see that
TABLE 2-14
, you would need to replace this DIMM.
displays a sample
2
C Diagnostic Test
dimm-spd@0,b6
test were to
i2c@0,320