2. Turn off the diag-switch? and diag-script variables. Type:
ok setenv diag-switch? false
ok setenv diag-script none
3. Set OpenBoot configuration trigger variables to bypass diagnostics. Type:
ok setenv post-trigger none
ok setenv obdiag-trigger none
What Next
The Sun Fire V440 server is now configured to minimize the time it takes to reboot.
If you change your mind and want to force diagnostic tests to run, see:
"How to Put the System in Diagnostics Mode" on page 57

How to Bypass Diagnostics Temporarily

Before You Begin
The ALOM system controller provides a "back-door" method of skipping diagnostic
tests and booting the system. This procedure is only of assistance in those unusual
circumstances where:
The system is configured to run diagnostic tests automatically on power up.
The hardware is functional and capable of booting, but is precluded from doing
so by a firmware malfunction or incompatibility.
What to Do
1. Log in to the ALOM system controller and access the sc> prompt.
Chapter 3
Isolating Failed Parts
59