Finally, this command reports on the status of motherboard circuit breakers (labeled
MB.FF_SCSIx) and CPU module DC-to-DC converters (labeled Cn.P0.FF_POK).
CODE EXAMPLE 4-6
----------------------
Current sensors:
----------------------
Sensor
----------------------
MB.FF_SCSIA
MB.FF_SCSIB
MB.FF_POK
C0.P0.FF_POK
C1.P0.FF_POK
C2.P0.FF_POK
C3.P0.FF_POK
4. Type the showfru command.
sc> showfru
This command, like the Solaris operating environment command prtfru
displays static FRU-ID information as available for several system FRUs. The specific
information provided includes the date and location of manufacture, and the Sun
part number.
CODE EXAMPLE 4-7
FRU_PROM at PSO.SEEPROM
Timestamp: MON SEP 16 16:47:05 2002
Description: PWR SUPPLY, CHALUPA,75%-EFF,H-P
Manufacture Location: DELTA ELECTRONICS CHUNGLI TAIWAN
Sun Part No: 3001501
Sun Serial No: T00065
Vendor JDEC code: 3AD
Initial HW Dash Level: 01
Initial HW Rev Level: 02
Shortname: PS
84
Sun Fire V440 Server Diagnostics and Troubleshooting Guide • July 2003
ALOM Reports on Circuit Breakers and DC-to-DC Converters
Status
OK
OK
OK
OK
OK
OK
OK
ALOM Reports on FRU Identification Information
,
-c