Display Par.
DCF INIT. LEVEL ( z )
OLD xx NEW yy
Value xx/yy : from 1 to 32
Function : Defines the value of the cutoff frequency of the Cutoff and the amount of E.G.Level a
minimum dynamics.
Depending on the value of DCF INIT.LEVEL we have for example:
1.If you play softly, both the cut-off frequency and the amount of E.G.Level will be
minimums, while playing loudly will be those set by the Cutoff and
E.G.Level. we will have at our disposal the maximum dynamic extension of the filter.
32. Both when playing softly and loudly the values of the cut-off frequency and
E.G.Level
will always be those set by the relevant parameters, we will have at our disposal a
keyboard without filter dynamics.
Parameter : DCA 1 TRHS OFF
Power meter : D
Display Par.
DCA1 TRHS OFF ( z )
OLD xx NEW yy
Value xx/yy : from 1 to 32
Function : Adjusts a level of dynamics beyond which DCA 1, and thus the entire generation
sound of Oscillator 1 , is switched off.
Depending on the value of DCA1 TRHS OFF we will have, for example:
1. DCA 1 is never activated.
16. DCA 1 will be deactivated if you exceed, during execution, half a level of
dynamics.
32. DCA 1 is never deactivated.
Parameter : DCA 2 TRHS ON
Power meter : E
Display Par.
DCA2 TRHS ON ( z )
OLD xx NEW yy
Value xx/yy : from 1 to 32
Function : Adjusts a level of dynamics beyond which DCA 2, and thus the entire generation