Family No. 5 : OSC. 1 Display Fam. : OSCILLATOR 1
Group : TUNE & FREQUENCY E.G TUNE - FREQ EG
________________________________________________________
Parameter : SEMITON
Power meter : A
Display Par.
OSC 1 SEMITON ( z )
OLD xx NEW yy
Value xx/yy : from - 5 to + 5
Function : Selects the tuning, in semitones, of the First Oscillator with respect to the tuning
General (Tune) of the instrument.
Parameter : FINE TUNE
Power meter : B
Display Par.
OSC1 FINE TUNE ( z )
OLD xx NEW yy
Value xx/yy : -7 to +7
Function : Selects the fine tuning of the First Oscillator with respect to tuning
General (Tune) of the instrument.
Parameter : E.G LEVEL
Power meter : C
Display Par.
FREQ EG LEVEL ( z )
OLD xx NEW yy
Value xx/yy : from - 15 to + 15
Function : Sets the frequency to which the first oscillator should tend via its envelope.
frequency, adjusted by the subsequent Attack and Decay parameters.
Parameter : ATTACK
Power meter : D
Display Par.
ATTACK TIME 1 ( z )
OLD xx NEW yy
Value xx/yy : from 1 to 16