Function : Determines the level at which the decay function of the amplifier of each voice
Oscillator 2 must stop. The Break Point is a level adjustment and not a
time such as Attack, Decay and Release.
Parameter : SLOPE
Power meter : D
Display Par.
SLOPE TIME 2 ( z )
OLD xx NEW yy
Value xx/yy : 1 to 31 + inf.
Function : Determines the time that the amplifier of each Oscillator 2 item takes to
from the level established by the Break Point parameter to the level established by
the
Sustain parameter. If the value of the Sustain parameter is greater than the value of
Break Point with the Slope we can determine the time of a second Attack.
If the value of the Sustain parameter is less than the Break Point with the Slope
we can determine the time of a second Decay. If the value of Slope
is set to inf. (infinity) ) the level of the amplifier will remain the one determined
by the Break Point parameter and will be held until the key is released and will not be
Sustain function enabled.
Parameter : SUSTAIN
Power meter : E
Display Par.
SUSTAIN LEVEL ( z )
OLD xx NEW yy
Value xx/yy : from 1 to 64
Function : Determines the level to which the amplifier of each Oscillator 2 voice should rise.
from the previous Break Point level in the time set by the Slope parameter.
If the Sustain value is equal to the Break Point value, the Slope function will be
ineffective.
Parameter : RELEASE/PED
Power meter : F
Display Par.
RELEASE TIME 2 ( z )