Function
Description
MC Defrost start
Master control signal for starting a defrost. At adap-
tive defrost the defrost might be skipped if the de-
frost is not needed
MC Defrost state
Read out the actual state of the defrost
MC Hold after de-
Master control signal used for co-ordinated defrost
frost
control to hold cabinets from returning to normal re-
frigeration after a defrost until all cabinets have termi-
nated defrost
MC Stop defrost
Master control signal used to prevent a defrost start in
a controller.
MC Light signal
Master control signal for control of light via a data
communication signal from the system manager
MC Actual dewpoint Master control signal sending the actual measured
dewpoint from the system manager to the controller
over the network.
MC Po load factor
MC Key/Bluetooth
Master control signal that will lock down all Bluetooth
lock
data communication and optionally also the opera-
tion of the display keys (depend upon selection in
P89 Display keyboard lock)
MC Min. delta T
Required minimum delta temperature across evapo-
rator (S3 - Te) in order to keep the air temperature at
the actual setpoint
No. of case sections No. of sections in the case

Fault message

In an error situation the alarm LED on the front will be on and the alarm relay will be activated (depending on
priority). If you push the alarm button for 3 seconds you can see the alarm report in the display. (Alarm priorities can
be changed. See
Table 39: Alarm relay
Code
Alarm text
E01
Hardware failure
E06
Clock lost time
E20
Pe Evap. pressure A - Sensor error
E24
S2 Gas outlet A - Sensor error
E26
S4 Air OFF evap. A - Sensor error
E27
S5 Evaporator A - Sensor error
E37
S5 Evaporator B - Sensor error
E59
Humidity sensor - Sensor error
E60
S4 Air OFF evap. B - Sensor error
E61
S4 Air OFF evap. C - Sensor error
E62
S2 Gas outlet B - Sensor error
E63
S2 Gas outlet C - Sensor error
A01
High temperature alarm A
A02
Low temperature alarm A
A04
Door open alarm
A05
Max defrost hold time exceeded
A11
Refrigerant not selected
A15
DI alarm 1
A16
DI alarm 2
A45
Main switch set OFF
A59
Case in cleaning mode
A70
High temperature alarm B
A71
Low temperature alarm B
CO
leak detected
AA2
2
AA3
Refrigerant leak detected
a02
High humidity alarm
a03
Low humidity alarm
a05
High temperature alarm C
a06
Low temperature alarm C
© Danfoss | Climate Solutions | 2022.08
Values
0=OFF, 1=ON
0=OFF, 1=ON
0=OFF, 1=ON
0=OFF, 1=ON
0=OFF, 1=ON
0=OFF, 1=ON
priorities.) Here are the messages that may appear:
Description
The controller has a hardware failure
Clock has lost valid time
Sensor signal is out of range. Please check the sensor for correct operation
Sensor signal is out of range. Please check the sensor for correct operation
Sensor signal is out of range. Please check the sensor for correct operation
Sensor signal is out of range. Please check the sensor for correct operation
Sensor signal is out of range. Please check the sensor for correct operation
Sensor signal is out of range. Please check the sensor for correct operation
Sensor signal is out of range. Please check the sensor for correct operation
Sensor signal is out of range. Please check the sensor for correct operation
Sensor signal is out of range. Please check the sensor for correct operation
Sensor signal is out of range. Please check the sensor for correct operation
The alarm temperature has been above the max alarm limit for a longer time period than the set alarm delay.
The alarm temperature has been below the min alarm limit for a longer time period than the set alarm delay.
The door has been open for a too long time
The controller has been waiting longer time than permitted after a co-ordinated defrost.
The refrigerant has not been selected hence control can not be initiated
Alarm signal from digital input signal
Alarm signal from digital input signal
The controller manin switch has been set to either Stop or Manaual control. Alternatively a digital input set up for
"main switch" function, has stopped control
A case cleaning operation has been started on a case
The alarm temperature has been above the max alarm limit for a longer time period than the set alarm delay.
The alarm temperature has been below the min alarm limit for a longer time period than the set alarm delay.
CO
is leaking from the refrigerantion system
2
Refrigerant is leaking from the refrigeration system
The humidity level is too high
The humidity level is too low
The alarm temperature has been above the max alarm limit for a longer time period than the set alarm delay.
The alarm temperature has been below the min alarm limit for a longer time period than the set alarm delay.
Code
Short name
x13
--- MC def.start
x14
--- DefrostState
x11
--- HoldAfterDef
x12
--- Disable def.
o39
o39 Light remote
x03
--- Act.DewPoint
x83
--- Load factor
x33
--- Key/BT Lock
y04
--- Min Delta T
z05
--- NoOfEvap