Siemens SINAMICS G120D Operating Instructions Manual page 323

Distributed converter, control units with encoder evaluation
Hide thumbs Also See for SINAMICS G120D:
Table of Contents

Advertisement

Function
12
SINAMICS "Standard Drive Control" and "Dynamic Drive Con-
trol" application classes to simplify commissioning and increase
the degree of ruggedness of the closed-loop motor control.
The SINAMICS application classes are available with the fol-
lowing inverters:
SINAMICS G120C
SINAMICS G120 with PM240, PM240-2 and PM330 Power
Modules
13
Moment of inertia estimator with moment of inertia precontrol to
optimize the speed controller in operation
14
Friction torque characteristic with automatic plotting to optimize
the speed controller
15
Automatic optimization of the technology controller
16
The sign of the system deviation for the additional, free tech-
nology controller can be switched over.
A new parameter defines the sign of the system deviation
matching the particular application, e.g. for cooling or heating
applications.
17
The technology controller output can be enabled and disabled
during operation
18
Ramp-function generator remains active with enabled technol-
ogy controller
19
Line contactor control using a digital output of the inverter to
save energy when the motor is switched off
20
Fast flying restart for PM330 Power Modules:
The "Flying restart" function does not have to wait for the motor
demagnetization time, and identifies the motor speed without
requiring a search operation.
21
Load torque monitoring extended to include the following func-
tions:
Protection against blocking, leakage and dry running opera-
tion in pump applications
Protection against blocking and broken belts in fan applica-
tions
22
Automatic switchover of the real time clock from daylight saving
time (summer time) to standard time (winter time).
23
New or revised default settings of the interfaces: p0015 macros
110, 112 and 120
24
Expansion of the temperature sensors to include DIN-Ni1000
for analog inputs AI 2 and AI 3
25
Communication via AS-Interface.
Default setting of the communication via AS-i: p0015 macros
30, 31, 32 and 34
26
Communication expansion via Modbus:
Adjustable parity bit, access to parameters and analog inputs
Converter with control units CU240D-2
Operating Instructions, 07/2016, FW V4.7 SP6, A5E34262100B AD
A.1 New and extended functions
SINAMICS
G120
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Appendix
G120D
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
323