Table 6- 27
Parameter
p1300
p0300 ...
p0360
p1511
p1520
p1521
p1530
p1531
Additional information about this function is provided in the parameter list and in function
diagrams 6030 onwards in the List Manual.
Converter with control units CU240D-2
Operating Instructions, 07/2016, FW V4.7 SP6, A5E34262100B AD
The most important torque control parameters
Description
Control mode:
22: Torque control without speed encoder
Motor data are transferred from the motor rating plate during quick commissioning and
calculated with the motor data identification
Additional torque
Upper torque limit
Lower torque limit
Motoring power limit
Regenerative power limit
Advanced commissioning
6.5 Motor control
175