12. TROUBLESHOOTING
Troubleshooting
Some Memory channels cannot be selected using the microphone keypad.
z The selected Memory channel is not yet entered�
→Rotate [DIAL] to check whether or not the channel has been entered�
The scan does not start.
z The squelch is open�
→Rotate [SQL] to adjust the squelch level to the threshold point� See the Basic manual for details�
z The same frequencies are entered into the Scan Edge channels�
→Enter different frequencies into the Scan Edge channels. (p. 4-10)
z Only one Memory channel is entered, or other channels are set as Skip channels�
→Enter other Memory channels or clear the Channel Skip setting in the desired channels� (p� 4-11)
z The Priority watch function is activated�
→Cancel the watch� (p� 5-4)
Transmission is automatically cut off.
z The Time-out timer is activated�
→Turn OFF the timer� (p� 8-5)
Transmission continues even when [PTT] is released.
z The One-touch PTT function is activated�
→Turn OFF the function� (p� 9-4)
The function display shows erroneous information.
z The CPU is malfunctioning�
→Reset the CPU� (p� 9-5)
12-3
Need help?
Do you have a question about the IC-V3500 and is the answer not in the manual?
Questions and answers
What is connection of 3.5 mm stereo connector for external speaker for icom ic-v3500?