The trigger status icon also appears in the title bar of the minimized trigger setup window.
This is useful for monitoring the trigger status of multiple ILA cores.
Detailed trigger and capture status information also appears in the Messages pane (or
console window).
Waveform Window
To view the waveform for a particular ILA core, select Window > New Unit Windows, and
the core desired. A dialog box appears for that ChipScope Pro core unit, and you can select
the Trigger Setup, Waveform, Listing, and/or Bus Plot window, or any combination.
Windows cannot be closed from this dialog box. The same operation can be achieved by
double-clicking on the Waveform leaf node in the project tree, or right-clicking on the
Waveform leaf node and selecting Open Waveform.
The Waveform window displays the sample buffer as a waveform display, similar to many
modern simulators and logic analyzers. All signal browser operations can also be
performed in the waveform window, such as bus creation, radix selection, and renaming.
To perform a signal operation, right-click a signal or bus in the Bus/Signal column.
Bus and Signal Reordering
Buses and signals can be reordered in the Waveform window. Select one or more signals
and buses, and drag it to its new location. A red line shows the potential drop location.
Note:
by using the Alt-UpArrow and Alt-DownArrow keystroke combinations.
Cut/Copy/Paste/Delete Signals and Buses
Signals and buses can be cut, copied, pasted, or deleted using right-click menus. Select one
or more signals and/or buses, right click a selected signal or bus, and select the operation
desired. Alternatively, the standard Windows key combinations are available (Ctrl+X for
cut, Ctrl+C for copy, Ctrl+V for paste, Del for delete).
Zooming In and Out
Select Waveform > Zoom > Zoom In to zoom in to the center of the waveform display, or
right-click in the waveform section and select Zoom
waveform, use Waveform > Zoom > Zoom Out, or right-click in the waveform and select
Zoom > Zoom Out.
To view the entire waveform display select Waveform > Zoom > Zoom Fit, or right click in
the waveform and select Zoom > Zoom Fit.
To zoom into a specific area, just use the left mouse button to drag a rectangle in the
waveform display. After the drag is complete, a popup appears. Select Zoom Area to
perform the zoom.
To zoom in to the space marked by the X and O cursors, select Waveform > Zoom > Zoom
X, O, or right-click in the waveform and select Zoom > Zoom X, O. Other zoom features
include zooming to the previous zoom factor by selecting Zoom > Zoom Previous,
ChipScope Pro Software and Cores User Guide
UG029 (v14.3) October 16, 2012
A spinning, partially filled pie icon indicates that the trigger and/or capture logic is
active
A solidly filled pie icon indicates the capture buffer is full and the trigger logic is idle.
Signals can be moved within a bus by first selecting one or more signals within the bus, then
www.xilinx.com
ChipScope Pro Analyzer Features
>
Zoom In. To zoom out from a
73