5
5.1
1.888.610.7664
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.

Vertical System

This series oscilloscope provides 2 analog input channels (CH1-CH2) for DHO1072/
DHO1102/DHO1202 and 4 analog input channels (CH1-CH4) for DHO1074/
DHO1104/DHO1204, and each channel is equipped with an independent vertical
control system. The setting methods for their vertical systems are the same. This
chapter takes CH1 of a four-channel model as an example to introduce the setting
method for the vertical system.
When a channel is selected, click or tap the channel status label at the bottom of the
screen. Then the menu as shown in the figure below is displayed.

To Enable or Disable the Analog Channel

Enable the Analog Channel
When a signal is connected to CH1, you can enable the channel in the following ways.
Click or tap the channel status label at the bottom of the screen to enable the
channel.
Press the front-panel key
key is illuminated.
Vertical System
In
switch to turn CH1 on or off.
When CH1 is activated, its status label at the bottom of the screen is as shown in the
figure below.
www.calcert.com
15
10
20
5
25
0
30

Figure 5.1 Vertical Menu

to enable the channel, and the backlight of this
menu, select the CH1 tab. Click or tap the Display on/off