D
ISMOUNTING
Dismount the elements which are in contact with
the front lower panel .
Detach the welding points of the front lower panel
(1) which are in connection with :
- floor closing plate in the area (2);
- front pillar in the (3) area;
- in the length of the area (4) with floor closing
plate;
- side panel in the area (5);
- central pillar in the area (6).
Straighten the areas resulted by dismounting.
Grind the areas resulted by dismounting.
R
EMOUNTING
Position and center the new element .
Check the correct positioning of the front lower
panel .
Weld the front lower panel (1) following the
assembling outliners 2, 3, 4,5,6.
Straighten with the autogenous welding the (3) are a
with the front pillar, the (6) area with the central pillar
and the (5) area with side panel.
Leave open the water evacuation holes from the
front lower panel.
UPPER SIDE STRUCTURE
FRONT LOWER PANEL
43
2
-3
43
1
6
5
4
3