Troubleshooting Procedures

When the FF-SB Series safety light curtains are working properly and the sensing field is not
interrupted, the emitter LEDs E1 and E2 (yellow) are both illuminated, the receiver LED R3
(green) is illuminated, and all other LEDs are NOT illuminated. If this condition is not met,
refer to the following troubleshooting chart, flow diagram (see figure 4-3) and corresponding
repair procedures.
Troubleshooting Chart
Symptom
All light emitting diode
(LED) indicators are
NOT illuminated
LED E1, E2, R1, R2
and R4 are illuminated
LED E1 and R2 are
illuminated, R4 and E2
are NOT illuminated
LED E1, E2 and R2 are
illuminated, R4 is
flickering
LED E1, E2 and R3 are
illuminated, R1 is
flickering
Random alarms without
apparent cause (i.e.,
erratic outputs,
flickering LEDs)
LEDs E1, E2 and R3
are NOT illuminated, or
other LEDs are
illuminated.
For application help: call 1-800-537-6945
(see figure 4-2 for indicator information)
Probable Cause
No power.
Test input is open.
Sensing field may be
obstructed
Emitter and/or receiver
units need to be
cleaned
Emitter and/or receiver
units need to be
aligned
Emitter and/or receiver
unit internal error
Light curtain is in cycle
start mode
Emitter and/or receiver
units is contaminated
Emitter and/or receiver
units is misaligned
Line voltage transients
greater than IEC 801-4
Norm standard
Unacceptable ambient
light interference
External relays may not
be working.
Corrective Action
Ensure fuse is not blown (see Fuse Replacement procedure).
Ensure supply voltage is correct; as specified (see Specifications).
Ensure electrical power connections are secure and correct. (see
Electrical Connections chapter).
Ensure the external circuit wiring connection between pins C4 and B3
on the receiver connector is secure (see Electrical Connections
chapter).
On pre-1996 wiring, ensure the external circuit wiring between pins
C4 and C5 on the receiver connection is secure (see Electrical
Connections chapter).
Remove obstacles interrupting sensing field.
Clean emitter lens, receiver lens and mirrors (see Emitter and
Receiver Cleaning).
Align emitters, receiver and mirrors.
Replace emitter and/or receiver unit.
Ensure monitoring loop connections between pins C3 and C5 are
secure. (see Electrical Connections chapter).
Press cycle-start push button.
Clean emitter lens, receiver lens and mirrors (see Emitter and
Receiver Unit Cleaning section).
Align emitters, receiver and mirrors.
Ensure the correct supply voltage is provided (see Electrical
Connections chapter).
Ensure RC elements on the inductive loads are present (see
Electrical Connections chapter).
Ensure external circuit connection to pins C4 and C5 on the receiver
connector are secure (see Electrical Connections chapter).
Ensure ground connection on emitter and receiver are secure (see
Electrical Connections chapter).
Use a special optical filter (see Order Guide).
Refer to system wiring diagram and ensure the external relays
connected to or linked with the safety light curtain are operating
properly (see Electrical Connections chapter).