Scanning Range - Honeywell SYA14 Series Manual

Safety light curtains
Table of Contents

Advertisement

Response Times
The response time of FF-SB Series light curtains is the maximum time it takes the light curtain
to generate a stop signal after the sensing field has been interrupted. See the table below for
response times for individual light curtains.
Protected Heights (mm/in)
200 (7.87)
400 (15.75)
600 (23.6)
800 (31.5)
1000 (39.37)
1200 (47.24)
1400 (55.12)

Scanning Range

Figure 1-7 Scanning Range Diagram
Scanning range is the maximum distance allowed between the emitter and the receiver (see
figure 1-7). The FF-SB Series light curtains have the following scan ranges:
Product
FF-SB12
FF-SB14 (standard version)
FF-SB14 (filter version for crowded areas or
welding applications)
FF-SB30
FF-SB15
FF-SB12E/R02E-52
18 Honeywell • MICRO SWITCH Sensing and Control
Response Times (milliseconds)
FF-SB12
FF-SB14/FF-SB30
25
27
25
29
26
27
28
29
30
Scan Range
0 to 10 meters (0 to 32.8 feet)
0 to 10 meters (0 to 32.8 feet)
0 to 6 meters (0 to 19.7 feet)
0 to 6 meters (0 to 19.7 feet)
3 to 24 meters (9.84 to 78.8 feet)
0 to 6 meters (0 to 19.7 feet)
FF-SB Series Installation Manual
FF-SB15
25
26
27
For application help: call 1-800-537-6945

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sya30 seriesSya60 series