Honeywell SYA14 Series Manual page 603

Safety light curtains
Table of Contents

Advertisement

Wiring diagram
Connection of the restart push-button :
Figure 4.16 :
+24Vdc
2.5A max.
P/B3
K1
K2
32
27
26
+24V
OUTPUT
RESTART
FF-SRM
2
Machine
control
K2
circuitry
K1
0V
(*) : protect the FSDs relay coils with a varistor
4.8.3 MUTING LAMP output (terminal 4)
The IEC/EN 61496-1 norm makes mandatory the use of a white lamp which indicates to the
operators that a muting sequence is being performed, and that the protective equipment is
inactive. The " MUTING LAMP " output is permanently self-checked, and correct operation
of the lamp is monitored each time the muting sequence starts (open circuit and short-circuit
detection). An orange LED indicator located on the front cover gives an indication of the
external lamp status.
107004-15 EN FR26 ROW 0899 Printed in France
FSD
K1 *
25
OSD1
OSD2
8
FSD
K2 *
69